Kenan Auditorium does not provide cable for the installation of your rental package. All feeder cable, and tapping Ts for the purpose of utilizing any portable dimmer racks, including those owned and retained by Kenan Auditorium, must be provided by the renter. All stage pin jumpers, twofers and adapters must also be provided for by the renter for the installation of your rental package.
All DMX required for portable racks is also required to be provided by the renter
Grand Drape, red velour. Line set one, on traveler track. Can be drawn or flown
Mid-stage traveler, black velour, line set 11, on traveler track. Can be drawn or flown
Rear traveler, black velour, line set 20, on traveler track. Can be drawb or flown
All other curtains are black velour legs (6' x 20' (2m x 6.5m))
All soft goods are flame-resistant
Sky drop (white) is hung on line set 19
Fire Curtain (asbestos front drop) has manual operating lines on stage right, emergency line-cut releases on both sides, as well as temperature-activated releases in the grid
Please note that there are sets of DEAD HUNG LEGS between linesets 15-16 and 16-17 and a DEAD HUNG BORDER between linesets of 15-16.
Piano Garage:
Piano garage sits at 31'10" from plaster wall and cannot be moved leaving an 11" crossover space on the stage right side.
Accoustical Shells
Accoustical shells nest at the back wall opposite the piano garage and although can be moved, must be stored in the theatre space. They also allow for only an 11" crossover on the stage left side.
The Kenan Auditorium does not supply color media. Being a state agency in a town with no theatrical supply house, purchasing and receiving these items requires an average of three weeks.
Power source is located DR, approximately 10' (3m) from proscenium arch. Company Connection/Road Show Power availability is two-200 amp VAC fused disconnect switches, 3-phase 120/208 volt, 4-wire ed from one 400 amp breaker. This power supply can be used in addition to or seperately from stage lighting system. Camlock connectors are permentantly installed to each panel and are available for use by the renter.
Control board, ETC Element 60/500, located in the rear of the balcony
Dimmers available are located in 2 ETC Sensor racks totaling 96 fully dimmable circuits. House and non-dim controls are housed in a Paradigm Architectural Control Center and is fully integrated with the house system.
Patch control is computerized. Headset stations are available.
All lighting positions require 2-pin and Ground 20 amp connectors.
All electric trusses have two schedule 80 pipes. Instruments can be double hung (above and below the wireway) if desired. Trim height is no greater than 20'
Balcony rail lighting is approximately 60' (20m) from the plaster line. Four circuits are available to feed six (6) PAR 56 units, used as curtain warmers. Dimmers 15-18
Ceiling ports, approximate 40' (13m) from plaster line, Dimmers 1 - 14 with dimmer 1 repeating on the stage left and right pipe ends and dimmer 8 repeating at the center.
First Electric: 3' 8" (1.2m) upstage of plaster line. 11 twenty amp circuits on 1'6" (.5m) centers. Can be flown to floor. Dimmers 19 - 29.
Second Electric: 10' 6" (3.6m) upstage of plaster line. 11 twenty amp circuits. Can be flown to floor. Dimmers 30 - 40.
Soft Electric: 15' 10" upstage of the midstage traveler. 12 twenty amp circuits. Can be flown to the floor. Dimmers 63-74.
Third Electric: 21' 3" (7m) upstage of plaster line. 3 11 twenty amp circuits. Can be flown to floor. Dimmers 41 - 51.
Fourth Electric: 29' (9.5m) upstage of plaster line. 5 11 twenty amp circuits. Prehung with 8 LED Spectre Series Cyc 200. Dimmers 52 - 62.
Floor pockets: Three positions on each side, under 1st, 2nd and 3rd electrics, paired circuits in each pocket. Dimmers 75 - 80
Boxboom located House left and Right in front of the Balcony. Dimmers 81-86 and 87-92
Pit circuits, 4 available Dimmers 93-96. Are paired with the wall pockets stage right and left proscenium.
Eight pipes (trees) available for sidelighting on stage.
Power source is located DR, approximately 10' (3m) from proscenium arch. Company Connection/Road Show Power availability is two-200amp VAC fused disconnect switches, 3-phase 120/208 volt, 4-wire fed from one 400amp breaker. This power supply can be used in addition to or separately from stage lighting system. Camlock connectors are permentantly installed to each panel and are available for use by the renter.